Description
Criticare nGenuity Patient Monitor
Criticare’s nGenuity 8100E Series Patient Monitor is the ideal solution for monitoring conscious sedation or post-procedure recovery. The system is extremely simple to use and easy to read from across the room, with bright and large color display and numeric readings. With a user-configurable display, clinicians are able to quickly and easily access results that they need.
Includes a 2-year parts and labor warranty.
Standard Features:
- ECG, ComfortCuff NIBP, DOX SpO2, Heart Rate, Temperature, Respiration, and Nurse Call interface connection
- Mini-Trends display of condensed tabular vital signs data to show recent monitoring activity
- Quick and easy mounting to walls and rollstands
- Compatible with common Electronic Medical Records (EMR) systems for both small and large offices
- 10” TFT display
- Simplified menus and dedicated function keys
Optional Features:
- End-tidal and inspired CO2, arrhythmia and ST analysis and integrated printer
- CO2 monitoring includes CSI’s patented water trap design with full occlusion clearing
Specifications:
ECG:
- Number of Leads: 3-or 5 Lead
- Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead); II, II or III (3-Lead)
- Gain Selection: x0.5, x1, x2, and x4
- Frequency Response:
- Diagnostic: 0.05 to 100 Hz (-3dB)
- Monitor: 0.5 to 40 Hz (-3dB)
- ST: 0.05 to 40 Hz (-3dB)
- Electrosurgery Protection: Yes
- Defibrillator Protection: Yes
- Pacer Detection/Rejection: Yes
- ST Accuracy: ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
- ST Range: -6.0 to 6.0 mm
NIBP:
- Technique: Oscillometric measure upon inflation
- Inflation Range:
- Adult/Pediatric: 0 to 300 mmHg
- Neonate: 0 to 150 mmHg
- Measurement Cycle: < 40 sec. typical; standard adult cuff
- Auto. Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals
- Max. Cuff Pressure:
- Adult/Pediatric: 300 mmHg
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater, over full range
- STAT Mode: 5 min of consecutive readings
- Clinical Accuracy: Complies with AAMI
Pulse Oximetry:
- Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified
- Method: Dual wavelength LED
Heart Rate:
- Source: User selectable – Smart, ECG, Pleth, NIBP
- Range: 20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP)
- Accuracy: ±1 bpm or ±1% (ECG) whichever is greater
Temperature:
- Channels: 1
- Probe: YSI-400 and YSI-700 Series
- Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
- Display Resolution: ±0.1°
Respiration:
- Rate: 6 to 150 bpm (ECG); 2 to 120 (CO2)
- Resolution: 1 breath/min
- Accuracy: ±1 breath/min
- Source: User selectable: Smart, CO2, ECG-TTI
Capnography (CO2):
- Units: mmHg, %; kPa; Torr; Percent
- Method: Non-dispersive infrared; auto calibrating
- N2O Compensation: Manual (On/Off, user selectable
- Range: 0 to 99 mmHg; 0 to 12.5%; 0 to 12.5 kPa; 0 to 99 Torr)
- Resolution: 1 mmHg; 0.1%; 0.1 kPa; 1 Torr flow
- Sample Rate: 200 ml/min
- Accuracy: ±2 mmHg; ±0.3 vol. %; ±0.3 kPa; or ±2 Torr at 200ml/min and respiratory rate of ≤ 120 Br/min
- Rise Time: 170 ms (10 to 90%) at 200 ml/min
Alarms:
- Indication: Audible; Visual
- Silence: Yes; 2 minutes or permanent
Trends:
- Memory: 24 hours at 30 second intervals with a NIBP reading every three minutes
- Display: Tabular, Graphical
Interface & Display:
- 9; membrane activated
- Rotary Knob: Push and rotate; 24 steps/turn
- Screen: 10.4” active color touch screen
- Resolution:
- Internal Display: 640 X 480 pixels
- External VGA Display: 640 X 480 pixels
- Waveform: 6 maximum
- Waveform Types: ECG leads I, II, III, aVR, aVL, AVF, V; CO2; Respiration; Pleth; ST Histograms
- Sweep Speed: 6.25, 12.5, 25, or 50 mm/sec
- Languages: English, Czech, French, German, Italian, Portuguese, Polish, Russian, Spanish, Turkish
- Control Keys: 10; membrane-activated
- Rotary Knob: Push and rotate; 2 steps/turn
System Outputs:
- COM Ports: RS232 compatible, DB9 (Com 1)
- Nurse Call: Contact switch; 3.5 mm stereo phone jack, 14 mm
- Defib/Sync: BNC connector
- Video Port: High density D-sub 15-pin
serial VGA compatible
Printer (Optional):
- Type: Thermal line printer
- 12.5, 25 or 50 mm/sec
Physical Properties:
- Weight: 14 lbs; 6.4 kg
- Size: 11 in (H) x 13 in (W) x 10.3 (D); 28 cm
(H) x 33 cm (W) x 26.2 cm (D)
Power Requirements:
- Voltage: 100 to 240 VAC; 50/60 Hz
- Power Consumption: 35 Watts, typical
- Battery: 1 sealed lead acid
- Power consumption: 35 W, typical
- Battery Life: 3 hours, typical (2.5 hours w/ CO2 hours)
- Power Consumption: 35 W, typical
- Recharge Time: 4.5 hours, typical
Environmental:
- Operating Temperature: 59° to 95°F (15° to 35°C)
- Storage Temperature: 23° to 122°F (-5° to 50°C)
- Operating Humidity: 15% to 90%, noncondensing
Classification:
- Medical Device: Class II Equipment (IIb EU)
- Electrical Protection: Class I Equipment
- Degree of Protection: Type CF, Defibrillator-proof
- Protection Against Ingress: IPX1
ECG:
· Number of Leads: 3-or 5 Lead
· Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead); II, II or III (3-Lead)
· Gain Selection: x0.5, x1, x2, and x4
· Frequency Response:
o Diagnostic: 0.05 to 100 Hz (-3dB)
o Monitor: 0.5 to 40 Hz (-3dB)
o ST: 0.05 to 40 Hz (-3dB)
· Electrosurgery Protection: Yes
· Defibrillator Protection: Yes
· Pacer Detection/Rejection: Yes
· ST Accuracy: ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
· ST Range: -6.0 to 6.0 mm
NIBP:
· Technique: Oscillometric measure upon inflation
· Inflation Range:
o Adult/Pediatric: 0 to 300 mmHg
o Neonate: 0 to 150 mmHg
· Measurement Cycle: < 40 sec. typical; standard adult cuff
· Auto. Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals
· Max. Cuff Pressure:
o Adult/Pediatric: 300 mmHg
o Neonate: 150 mmHg
· Resolution: 1 mmHg
· Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater, over full range
· STAT Mode: 5 min of consecutive readings
· Clinical Accuracy: Complies with AAMI
Pulse Oximetry:
· Range: 1% to 99%
· Resolution: 1%
· Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified
· Method: Dual wavelength LED
Heart Rate:
· Source: User selectable – Smart, ECG, Pleth, NIBP
· Range: 20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP)
· Accuracy: ±1 bpm or ±1% (ECG) whichever is greater
Temperature:
· Channels: 1
· Probe: YSI-400 and YSI-700 Series
· Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
· Display Resolution: ±0.1°
Respiration:
· Rate: 6 to 150 bpm (ECG); 2 to 120 (CO2)
· Resolution: 1 breath/min
· Accuracy: ±1 breath/min
· Source: User selectable: Smart, CO2, ECG-TTI
Capnography (CO2):
· Units: mmHg, %; kPa; Torr; Percent
· Method: Non-dispersive infrared; auto calibrating
· N2O Compensation: Manual (On/Off, user selectable
· Range: 0 to 99 mmHg; 0 to 12.5%; 0 to 12.5 kPa; 0 to 99 Torr)
· Resolution: 1 mmHg; 0.1%; 0.1 kPa; 1 Torr flow
o Sample Rate: 200 ml/min
· Accuracy: ±2 mmHg; ±0.3 vol. %; ±0.3 kPa; or ±2 Torr at 200ml/min and respiratory rate of ≤ 120 Br/min
· Rise Time: 170 ms (10 to 90%) at 200 ml/min
Alarms:
· Indication: Audible; Visual
· Silence: Yes; 2 minutes or permanent
Trends:
· Memory: 24 hours at 30 second intervals with a NIBP reading every three minutes
· Display: Tabular, Graphical
Interface & Display:
· 9; membrane activated
· Rotary Knob: Push and rotate; 24 steps/turn
· Screen: 10.4” active color touch screen
· Resolution:
o Internal Display: 640 X 480 pixels
o External VGA Display: 640 X 480 pixels
· Waveform: 6 maximum
· Waveform Types: ECG leads I, II, III, aVR, aVL, AVF, V; CO2; Respiration; Pleth; ST Histograms
· Sweep Speed: 6.25, 12.5, 25, or 50 mm/sec
· Languages: English, Czech, French, German, Italian, Portuguese, Polish, Russian, Spanish, Turkish
· Control Keys: 10; membrane-activated
· Rotary Knob: Push and rotate; 2 steps/turn
System Outputs:
· COM Ports: RS232 compatible, DB9 (Com 1)
· Nurse Call: Contact switch; 3.5 mm stereo phone jack, 14 mm
· Defib/Sync: BNC connector
· Video Port: High density D-sub 15-pin
serial VGA compatible
Printer (Optional):
· Type: Thermal line printer
· 12.5, 25 or 50 mm/sec
Physical Properties:
· Weight: 14 lbs; 6.4 kg
· Size: 11 in (H) x 13 in (W) x 10.3 (D); 28 cm
(H) x 33 cm (W) x 26.2 cm (D)
Power Requirements:
· Voltage: 100 to 240 VAC; 50/60 Hz
· Power Consumption: 35 Watts, typical
· Battery: 1 sealed lead acid
· Power consumption: 35 W, typical
· Battery Life: 3 hours, typical (2.5 hours w/ CO2 hours)
· Power Consumption: 35 W, typical
· Recharge Time: 4.5 hours, typical
Environmental:
· Operating Temperature: 59° to 95°F (15° to 35°C)
· Storage Temperature: 23° to 122°F (-5° to 50°C)
· Operating Humidity: 15% to 90%, noncondensing
Classification:
· Medical Device: Class II Equipment (IIb EU)
· Electrical Protection: Class I Equipment
· Degree of Protection: Type CF, Defibrillator-proof
· Protection Against Ingress: IPX1