GE CASE V6.7 Stress Monitor with T2100 Stress Treadmill

GE CASE V6.7 Stress Test Monitor
Standard with LAN, XML, and PDF exporting options for easy EMR or EHR connectivity
GE T2100 Stress Test Treadmill
220V T2100 Treadmill, Full Handrail Set, and Emergency Stop Included
1-Year Parts & Labor Warranty
Installation and Training Included
  • SKU
    2062898-001-504225

Setting the Standard for Cardiac Stress Testing

The GE CASE V6.7 stress test and T2100 treadmill are guaranteed to help improve diagnostic cardiac assessment while enhancing workflow in any testing environment. The GE CASE V6.7 now comes standard with exporting options such as LAN connectivity, Microsoft Word/Excel/XML and PDF export. Additional features included are network storage and local storage including a 40GB hard drive. Optional features include MUSE Connectivity, DICOM export, and 12SL resting ECG interpretation for adults and pediatrics. 

Standard ST measurements include amplitudes, slope, integral, index, ST/HR hysteresis, ST/HR slope, ST/HR loops, and ST/HR index (up to 15 leads). The CASE V6.7 also includes standard ECG/QRS/TTL output for stress echo with any cardiac ultrasound system. Full-Disclosure ensures beat-by-beat ECG storage for any type of event that needs to be reviewed during or after the test. Post-test measurements such as E, J, and post-J point allow for clinical post-review and confirmation for all cardiac events during the stress test.

The T2100 treadmill comes standard with a 220v connection, full handrail set, and an emergency stop. GE has recently released a brand new 110V treadmill compatible with the GE CASE V6.7 stress test controller which can be found here.   

All brand new systems include a full 1-year parts and labor warranty, excluding all accessories (Standard 90-day warranty on all accessories). Shipping charges include inside delivery and debris removal as well as 1-day onsite training and installation by a certified GE field engineer. All CASE V6.7 stress test systems ship patient ready with a CAM 14 acquisition module, GE Chart Paper (9402-024), and a sample pack of stress electrodes.

All additional consumables can be purchased below or in our supplies and accessories category. 

 

  • Manufacturer
    GE
  • Stress Test Type
    Complete Stress Test Systems
  • ECG analysis Frequency
    500 Hz
  • ST Measurements
    ST amplitudes, slope, integral, index, ST/HR hysteresis, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads
  • E, J and post-J point
    Manual or computer selected
  • Signal processing
    Incremental median updating technique
  • Baseline correction
    Finite Residual Filter (FRF) and/or Cubic Spline analysis
  • QRS detection and analysis
    Automatic or manual lead selection
  • ECG output
    Real-time ECG/QRS beep/TTL synchronization output
  • Full-disclosure ECG
    Beat-to-beat ECG storage & event review
  • Reanalysis
    Post-test medians measurements from E, J, and post-J point selections
  • ECG interpretation
    (Optional) Marquette 12SL resting EKG analysis program for adults and pediatrics
  • Additional EKG function
    XTI stress interprettaion Vectorcardiography (15 lead)
  • Data Acquisition Technology
    Active, “Type BF” floating isolated powered 14-channel acquisition module with built-in lead-fail detection and lead prep impedance measurement
  • Sampling Rate
    Over sampling @ 16000 Hz, 12 Leads
  • Skey
    62.5 µs
  • Dynamic range
    320 mV, ± 10 mV signal superimposed on ± 150 mV DC offset
  • Resolution
    4.88 µV/LSB @ 500 Hz
  • Noise
    < 15 µV peak-to-peak noise over 0.01 to 150 Hz (-3 dB) bandwidth
  • Frequency response
    -3 dB, display and writer
  • High-pass filter
    0.01 (or 0.05 Hz, special use) with DC offset control
  • Low-pass filter
    20, 40, 100, 150 Hz (selectable)
  • Line filter
    50.0 or 60.0 Hz notch filter (selectable)
  • Baseline correction
    Cubic Spline algorithm
  • Artifact/baseline correction
    Finite Residual Filter (FRF) analysis
  • Common mode rejection
    > 140 dB (123 dB with AC filter disabled)
  • Input impedance
    > 10 M Ohms @ 10 Hz, defibrillator protected
  • Patient leakage
    < 10 µA
  • Pace detect
    Orthogonal LA, LL and V6; 750 µV @ 50 µs
  • Local storage
    Minimum 40 GB hard drive storage of complete ECG record and test results
  • PDF export
    Yes
  • XML export
    Yes
  • Operating System
    Microsoft Win 7 Operation system, 64 bit.
  • HDD
    Min 250 GB
  • Processor
    Intel Celeron Mobile Processor Dual Core 1.9 Ghz 64 bit.
  • RAM
    2 GB standard, 4 GB optional
  • Display
    LCD 1280 * 1024 19"
  • Monitored Leads
    3, 6, 12 or 15
  • Displayed leads
    Number on screen 3, 6, 12, or 15
  • Display format
    3 rhythm, 3 rhythm + medians, 3 rhythm + trends, rhythm, 4 x 2.5 + 1 rhythm, 2x6
  • Display speeds
    25, 50 mm/s
  • Display sensitivity/gain 2
    2.5, 5, 10, 20 mm/mV
  • Displayed vital signs data (configurable)
    Heart rate, target heart rate, blood pressure, exercise clock, stage clock, phase clock, protocol, speed, grade, Watts, METS, RRP and SpO2
  • Other displayed data
    ST scan/median complexes, arrhythmias, ventricular ectopic/min. counter, 3 to 15 waveforms, lead check torso and 12 leads, waterfall displays, trends, tabular summary, stored ECG strips, interpretation, time-of-day clock, patient name, warning messages an
  • Writer technology
    “Instant” load, thermal dot array
  • Writer resolution
    Horizontal 1000 lines/sec x 200 dpi dedicated local printing. 200 x 200 dpi generic printing
  • Paper type
    Thermal, perforated, fan-fold, 300 sheets/pack
  • Paper size
    Letter size 214.6 mm x 280 mm (8.45 in. x 11 in, A4 size 210 mm x 280 mm (8.27 in x 11 in.)
  • Height
    148 cm (58 in) with no monitor installed (LCD display rotates vertical and horizontal for optimum viewing)
  • Width
    62 cm (24 in) with paper tray removed
  • Depth
    75 cm (30 in)
  • Weight
    68 kg (150 lb) without monitor
  • Wire paper tray
    31.75 cm x 23.50 cm (12.50 in x 9.25 in) Attaches to left side of CASE system
  • Acquisition module holder tray
    6.60 cm x 23.50 cm (2.6 in x 9.25 in) Attaches to right side of CASE system
  • Power supply
    AC operation only
  • Interfaces included
    Acquisition module - CAM 14
    Keyboard - alpha numeric
    Keypad - dedicated stress function keys
    Mouse
    Integrated Thermal Printer
    10 MB/100 MB/ 1 GB Ethernet -
    MUSE* compatibile
    USB ports - 4
    PS2 ports - 2
    Serial ports - 6; COM 1-2, COM A-D,
    treadmill, BP, ergometer, SpO2
    Analog port - 4; TTL (trigger) - 1;
    output (imaging sync) and analog
    device communication
    DVD/CD-RW drive: readable; Archive:
    CD-RW media only
    SD card

Recommended products

Drop items here to shop
Product has been added to your cart